Overhead view of multiple LVAD system components including cables, handles and control modules arranged on a white background.
Case Studies

Cardiac Recovery System

Client Snapshot

Client Snapshot

Cardiac Recovery System

StarFish was part of a multiple discipline team that developed an LVAD related system for animal testing. We were responsible for the packaging, Industrial Design, fluid and electrical inter-connectivity, power supply, user interface, and prototype fabrication. The system was comprised of an “Acute Controller/Console”, a “Chronic Controller Assembly” and “Telemetry-linked Clinical Console”.

3D rendering of the Cardiac Recovery System acute controller showing internal components, wiring paths and external housing design.
Rendered layout of LVAD recovery system controllers, connectors and tubing components arranged on a silver surface.
Team assembling and positioning LVAD recovery system equipment during preclinical animal testing in a laboratory environment.
Mannequin torsos demonstrating placement of the LVAD recovery system controller and connected tubing for clinical setup simulation.

Explore Other Case Studies

Technical patent drawing of an implantable orthopedic screw showing internal components and sensing architecture.

StarFish Medical helped Canary Medical develop a smart implantable screw using EIS to monitor fracture healing without repeated imaging.

Lumithera Units

LumiThera chose StarFish Medical for their expertise in navigating the path from late-stage prototype to commercial launch.

Theranostics represent a promising new frontier in cancer treatment, offering hope alongside a unique set of challenges for healthcare providers.

Abstract illustration of the human spine with a glowing focal point in the lumbar region

A leading research institution tackling the challenge of motor neuron degeneration in ALS developed a novel approach to treatment: deliver GDNF-secreting neural progenitor cells directly into the spinal cord to provide sustained neurotrophic support.

Explore Our Services

Illustration of a pencil and ruler

Our multidisciplinary teams have all the in-house capabilities to transform your medical device from concept to final product.

Illustration of a 3D cube

Medical device design and development with a commercial launch focus. See how we support clinical trials and facilitate seamless tech transfers.

Illustration of two speech bubbles

We help you navigate complex regulatory landscapes to achieve commercial success. Explore our integrated approach to quality and regulatory services.